Products

S-60

S-60

  Description

 

 

Features:
High efficiency, high reliability
Universal AC input / Full range
100% full load burn-in test
Protections: Short circuit / Over load / Over voltage
Cooling by free air convection
Fixed switching frequency at 50KHz
2 years warranty
Dimensions: 159*97*38mm(L*W*H)

SPECIFICATIONS
INPUT
Voltage Range 85~264 VAC47~63 Hz;120~370VDC
AC Current 2A/115 V 1A/ 230 V
Efficiency 73%(SKS-60-5); 76%(SKS-60-12); 77%(SKS-60-15); 79%(SKS-60-24); 80%(SKS-60-48);
Inrush Current Cold start 30A/115VAC 60A/230VAC
Leakage Current <3.5 mA/240VAC
PROTECTION
Over Load 135%~165%
Protection type: Fold back current limiting, recovers automatically after fault condition is removed.
Over Voltage 115%~135%
Protection type: hiccup mode, recovers automatically after fault condition is removed.
ENVIRONMENT
Working Temp., Humidity -10℃~+60℃;20%~90 %RH
Storage Temp., Humidity -20℃~+85℃;10%~95 %RH
Vibration 10~500Hz,2G 10min./1cycle,period for 60min, each long X, Y, Z, axes
SAFETY
Withstand Voltage I/P-O/P: 3KVACI/P-FG: 1.5KVACO/P-FG: 0.5KVAC
Isolation Resistance I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
STANDARD
Safety Standard Design refer to UL1012, UL1950,TUV EN60950
EMC Standard Design refer to EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11;ENV50204,EN55024
OTHERS
Weight 0.51Kg
Packing 24pcs/13.1Kg/0.7CUFT
NOTE 1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2.Ripple & noise are measured at 20MHz of bandwidth by using a 12″twisted pair-wire terminated with a 0.1μ &47μ
parallel capacitor.
3.Tolerance: includes set up tolerance, line regulation and load regulation
4.The power supply is considered a component which will be installed into a final equipment. The final equipment must
be re-confirmed that it still meets EMC directives.
OUTPUT
Model S-60-5 S-60-12 S-60-15 S-60-24 S-60-48
DC Voltage 5V 12V 15V 24V 48V
Voltage Tolerance ±2% ±1% ±1% ±1% ±1%
Rated Current 12A 5A 4A 2.5A 1.3A
Current Range 0-12A 0-5A 0-4A 0-2.5A 0-1.3A
Rated Power 60W 60W 60W 60W 62W
Ripple & Noise 120mVp-p 120 mVp-p 150 mVp-p 150 mVp-p 200 mVp-p
DC Adjustment Range -5%, +10% ±10% ±10% ±10% ±10%
Setup,Rise,Hold Time 750ms,50ms,10ms/115VAC300ms,50ms,80ms/230VAC

Popular Searches

Website on alibaba.com: http://leyuelec.preview.alibaba.com

Aliexpress.com Store: http://www.aliexpress.com/store/509864

Home  |  About Us  |  News  |  Products  |  Certificate  |  Download  |  Inquiry  |  Contact Us

Yueqing Leyu Electric Automation co.,Ltd .    ADD:Huarong Road, liushi Town, Yueqing City, Zhejiang, China
TEL: 86-577-62980983 62998958     Mobile:86-13757759294    FAX: 86-577-62981651