Products

DR-45-24

DR-45-24

  Description

 

 

 

 

Features:
Universal AC input/ full range
Protections: Short circuit/ Over load/ Over voltage/ Over temperature
Cooling by free air convection
Can be installed on DIN rail TS-35/7.5 or 15
LED indicator for power on
100% full load burn-in test
Fixed switching frequency at 100KHz
3 years warranty
Dimensions: 93*78*67mm (L*W*H)

SPECIFICATIONS
INPUT
Voltage Range 85~264 VAC47~63 Hz;selected by switch120~370VDC
AC Current 1.5 A/115 V 0.75A/ 230 V
Efficiency 72%(HDR-45-5); 77%(HDR-45-12); 77%(HDR-45-15); 80%(HDR-45-24)
Inrush Current Cold start 28A/115V 56A/230V
Leakage Current <1mA/240VAC
PROTECTION
Over Load 105%~150%
Protection type: Constant current limiting, recovers automatically after fault condition is removed
Over Voltage 115%~135%
Protection type: Shut down o/p voltage, re-power on to recover
Over Temp..

Tj 135 typically (U1) Detect on heat sink of power transistor,shut down o/p voltage, recovers automatically after temperature goes down

ENVIRONMENT
Working Temp., Humidity -10℃~+50℃;20%~90 %RH
Storage Temp., Humidity -20℃~+85℃;10%~95 %RH
Vibration 10~500Hz,2G 10min./1cycle, period for 60min, each along X, Y, Z axes
SAFETY
Withstand Voltage I/P-O/P: 3KVACI/P-FG: 1.5KVACO/P-FG: 0.5KVAC
Isolation Resistance I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC
STANDARD
Safety Standard Design refer to UL508,TUV EN60950-1
EMC Standard Design refer to EN55011,EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11,ENV50204,EN55024,EN61000-6-2
OTHERS
Weight 0.31Kg
Packing 48pcs/16.1Kg/1.3CUFT
NOTE 1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″twisted pair-wire terminated with a 0.1μ & 47μ
parallel capacitor.
3.Tolerance: includes set up tolerance, line regulation and load regulation.
4.The power supply is considered a component which will be installed into a final equipment. The final equipment must
be re-confirmed that it still meets EMC directives.
OUTPUT
Model DR-45-5 DR-45-12 DR-45-15 DR-45-24
DC Voltage 5V 12V 15V 24V
Voltage Tolerance ±2% ±1% ±1% ±1%
Rated Current 5A 3.5A 2.8A 2A
Current Range 0-5A 0-3.5A 0-2.8A 0-2A
Rated Power 25W 42W 42W 48W
Ripple & Noise 100mVp-p 200mVp-p 240mVp-p 480mVp-p
DC Adjustment Range 4.75-5.5V 10.8-13.2V 13.5-16.5V 21.6-26.4V
Setup, Rise, Hold Time 720ms,60ms,100ms/230VAC at full load

Popular Searches

Website on alibaba.com: http://leyuelec.preview.alibaba.com

Aliexpress.com Store: http://www.aliexpress.com/store/509864

Home  |  About Us  |  News  |  Products  |  Certificate  |  Download  |  Inquiry  |  Contact Us

Yueqing Leyu Electric Automation co.,Ltd .    ADD:Huarong Road, liushi Town, Yueqing City, Zhejiang, China
TEL: 86-577-62980983 62998958     Mobile:86-13757759294    FAX: 86-577-62981651