Products

S-150

S-150

  Description

150W Single Output Switching Power Supply        S-150 series

Features: 
High efficiency, high reliability
AC input range selected by switch
100% full load burn-in test
Protection: Short circuit/ Over load / Over voltage
Cooling by free air convection
Fixed switching frequency at 25KHz
1 year warranty

SPECIFICATIONS

OUTPUT

Model

S-150-5

S-150-9

S-150-12

S-150-13.5

S-150-15

S-150-24

S-150-27

S-150-48

DC Voltage 

5V

9V

12V

13.5V

15V

24V

27V

48V

Rated Current 

30A

16.7A

12.5A

11.2A

10A

6.5A

5.6A

3.2A

Current Range 

0-30A

0-16.7A

0-12.5A

0-11.2A

0-10A

0-6.5A

0-5.6A

0-3.2A

Rated Power 

150W

150.3W

150W

151.2W

150W

156W

151.2W

153.6W

Ripple & Noise 

150mVp-p

180mVp-p

180mVp-p

180mVp-p

180mVp-p

240mVp-p

240mVp-p

240mVp-p

Voltage Adj. Range

±10%

-12%;+15%

-12%;+10%

-12%;+11%

±10%

-12%;+16%

-12%;+11%

±10%

Voltage Tolerance 

±2%

±1%

±1%

±1%

±1%

±1%

±1%

±1%

Setup, Rise, Hold Up Time

100ms,50ms,20ms at full load

INPUT

Voltage Range 

88~132VAC/176~264VAC selected by switch   47~63Hz248~370VDC

AC Current

3.2A/115V   1.6A/230V

Efficiency

78%

80%

82%

83%

84%

85%

86%

87%

Inrush Current 

Cold start 35A/230VAC

Leakage Current

<3.5mA/240VAC

PROTECTION

Over Load 

110%~160% 

Protection type: Shut down o/p voltage, re-power on to recover

Over Voltage 

115%~135%

Protection type: Shut down o/p voltage, re-power on to recover

ENVIRONMENT

Working Temp., Humidity

-10~+6020%~90%RH

Storage Temp., Humidity

-20~+8510%~95%RH

Vibration

10~500Hz2G 10min./1cycleperiod for 60min, each along X, Y, Z axes

SAFETY

Withstand Voltage

I/P-O/P: 3KVAC   I/P-FG: 1.5KVAC   O/P-FG: 0.5KVAC

Isolation Resistance

I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC

STANDARD

Safety Standard

Design refer to UL1012, UL1950TUV EN60950

EMC Standard

Design refer to EN55022EN61000-3-2-3EN61000-4-23456811ENV50204EN55024

OTHERS

Dimension

199*110*50mm(L*W*H)

Weight

0.8Kg

Packing

16pcs/13.8Kg/0.95CUFT 

NOTE

1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.

2.Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1μ & 47μ parallel capacitor. 

3.Tolerance: includes set up tolerance, line regulation and load regulation 

4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 


 

Popular Searches

Website on alibaba.com: http://leyuelec.preview.alibaba.com

Aliexpress.com Store: http://www.aliexpress.com/store/509864

Home  |  About Us  |  News  |  Products  |  Certificate  |  Download  |  Inquiry  |  Contact Us

Yueqing Leyu Electric Automation co.,Ltd .    ADD:Huarong Road, liushi Town, Yueqing City, Zhejiang, China
TEL: 86-577-62980983 62998958     Mobile:86-13757759294    FAX: 86-577-62981651