Home | Applications | Solutions | Blogs | About Us | Contact Us
LDV Series Waterproof Power Supply->LDV-200
LEYU
Availability: | |
---|---|
Quantity: | |
SPECIFICATION | ||||||
OUTPUT | ||||||
Model | LDV-200-12 | LDV-200-24 | LDV-200-36 | |||
DC Voltage | 12V | 24V | 36V | |||
Rated Current | 16.5A | 8.3A | 5.5A | |||
Current Range | 0-16.5A | 0-8.3A | 0-5.5A | |||
Rated Power | 198W | 199W | 198W | |||
Ripple & Noise | 150mVp-p | 200mVp-p | 200mVp-p | |||
Voltage Tolerance | ±1% | ±1% | ±1% | |||
Inlet Stability | ±0.5% | ±0.5% | ±0.5% | |||
Load Stability | ±0.5% | ±0.5% | ±0.5% | |||
Setup, Rise, Hold Up Time | 200ms,20ms,30ms/230VAC | |||||
INPUT | ||||||
Voltage Range | 180~264 VAC 47~63Hz;255~373VDC | |||||
AC Current | 1.5A/230VAC | |||||
Efficiency | 82% | 84% | 85% | |||
Inrush Current | Cold-start current 40A/230VAC | |||||
PROTECTION | ||||||
Over Load | 105%~135% | |||||
Protection:Hiccup mode, recovers automatically after fault condition is removed | ||||||
Over Voltage | 15~17V | 30~32V | 42~44V | |||
Protection:Hiccup mode, recovers automatically after fault condition is removed | ||||||
High Tem. | ≥85℃ | |||||
Protection:cut off the output, recovers automatically after fault condition is removed | ||||||
ENVIRONMENT | ||||||
Working Temp., Humidity | -10℃~+60℃,20%~90%RH | |||||
Storage Temp., Humidity | -20℃~+85℃, 10%~95%RH | |||||
Temp. Coefficient | ±0.03%/℃(0-50℃) | |||||
Vibration | 10-500Hz,2G 10min,/1cycle,Period for 60min,Each axes | |||||
SAFETY | ||||||
Withstand Voltage | I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC | |||||
Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC | |||||
STANDARD | ||||||
Safety Standard | EN61347-1 EN61347-2-13 IP67 | |||||
EMC Standard | EN55015 EN61547 EN61000-3.4 CLASSB | |||||
OTHERS | ||||||
Dimension | 215*69*43(L*W*H) | |||||
Weight | 1.3Kg | |||||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. | |||||
Download:LDV-200.doc